STØNE Pro Systems installation

STØNE Pro Systems

Key Benefits

  • Two-component system: outdoor condenser + indoor distribution unit connected by refrigerant or water lines
  • Compact indoor cabinets requiring no additional clearance: Pro Split 20 in. x 13 in. (508 x 330 mm) / Pro Complete 24 in. x 24 in. (610 x 610 mm)
  • Simple installation — no extensive technical expertise required
  • Pro Complete also provides domestic hot water

Options

  • Choice of floor-standing/wall-mounted or recessed indoor unit
  • Available in five sizes (2⁠–⁠5 tons)

Controllers

  • Butler Pro Advanced Controller

STØNE Pro Diagram

STØNE ensures a continuous supply of domestic hot water… where cold water flows through a serpentine-shaped pipe system for instantaneous heating.

STØNE Pro system diagram

Key Specifications

Heating
47°FSTØNE Pro 30
Maximum capacity (Btu/h)123 Btu/h
Nominal capacity (Btu/h)103 Btu/h
Power (kW)6.8 kW
Efficiency4.4
5°FSTØNE Pro 30
Maximum capacity (Btu/h)82 Btu/h
Nominal capacity (Btu/h)65 Btu/h
Power (kW)6.3 kW
Efficiency3.0
Cooling
STØNE Pro 30
Maximum capacity (Btu/h)120 Btu/h
Nominal capacity (Btu/h)92 Btu/h
Power (kW)10.2 kW
Efficiency9.03
Operating Limits
Ambient TemperatureEntering Water TemperatureLeaving Water Temperature
Heating
-13°F68°F77°F
-13°F95°F113°F
14°F113°F131°F
100°F113°F131°F
100°F68°F77°F
Cooling
59°F54°F45°F
59°F86°F77°F
117°F86°F77°F
117°F54°F45°F
Heating
47°FSTØNE Pro 30
Maximum capacity (kW)36.1 kW
Nominal capacity (kW)30.2 kW
Power (kW)6.8 kW
Efficiency4.4
5°FSTØNE Pro 30
Maximum capacity (kW)24.0 kW
Nominal capacity (kW)19.1 kW
Power (kW)6.3 kW
Efficiency3.0
Cooling
STØNE Pro 30
Maximum capacity (kW)35.2 kW
Nominal capacity (kW)27.0 kW
Power (kW)10.2 kW
Efficiency9.03
Operating Limits
Ambient TemperatureEntering Water TemperatureLeaving Water Temperature
Heating
-25°C20°C25°C
-25°C35°C45°C
-10°C45°C55°C
38°C45°C55°C
38°C20°C25°C
Cooling
15°C12°C7°C
15°C30°C25°C
47°C30°C25°C
47°C12°C7°C

Trusted by leading brands worldwide